1. -by observing in real time all angles, changing the direction of the reamer or inserter the surgeon can adjust the position of the cup respectively, aiming the final Implant orientation to be inside the new redefined safe zone- adjusted by patient-specific pelvic tilt-(Operative inclination (OI) 43°±12°, anteversion (OA) 31°± 8°).
2. -by attaching the Case-Probe to certain clamp and attaching to the reamer or later to inserter, the surgeon can be oriented by observing in real time over the phones screen, six angles, Operative Anteversion (OA) and Inclination (OI), Radiographic Anteversion (RA) and Inclination (RI), Anatomical Anteversion (AA) and Inclination (AI) respectively .
3. During surgery, as long as the measured values of OI and OA are inside the above mentioned normal range, the printed colour in screen remains green, otherwise are printed in red colour.
4. -During surgery, as long as the measured values of RI and RA are between normal range, the printed colour in screen remains green, otherwise are printed in red colour.
5. The application take advantage of Augmented reality and merges it with Computer Assisted Orthopaedic Surgery (CAOS) techniques and principles in effort to help an orthopaedic surgeon during operation without the need of expensive CAOS equipment.
6. Malposition- outside safe zone increases the risk of complications namely decreased range of movements, increased rates of impingement, increased wear rates, recurrent dislocations, osteolysis, ‘squeaking’, leg-length discrepancy, and early failure rates.
7. a transparent sphere appears inside the real acetabulum centred over the centre of hip rotation and also in augmented reality the bony pelvis appears over the screen.
8. Placement of the acetabular cup during surgery can be performed by using free hand technique and or by alignment support frames on the Inserter.
9. Murphy AB and & The Safe Zone Range for Cup Anteversion Is Narrower Than for Inclination in THA William S.
10. -Pelvic tilt is measured as anterior pelvic plane (APP) Angle and printed over screen.
11. -QR-code Image attached over Passive Sensor acts as a dynamic reference base, the app updates the position of registered points in AR according to the new position of patient pelvis respectively without to reregister.
Если вам нравится NaviToolHip, вам понравятся Medical такие приложения, как; ТРЭК 2022; AL Individual; Евромед Омск; MedecinDirect | Consultez 24/7; ДИАЛАЙН; Attention Deficit ADHD Test; Optics Clinical Calculator; Animated Essential Atlas; Notfallmedikamente Pro 4; ЭФИ калипер; NEJM CareerCenter; Гипношарик; Аналоги лекарств, справочник; Аптека Апрель - заказ лекарств; Аптека Будь Здоров - лекарства; Аптека Ригла: купить лекарства; Аптека Живика; СМ-Клиника; Petstory: ветеринар онлайн; Аптека Миницен;